Electrical Polyimide Film

Electrical Polyimide Film

Polyimide film for electrical insulation: dielectric strength by thickness, 25-125 micron, slit to 8 mm. Class H, 260 C. Choose the film for your voltage class.

  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service
Product Introduction

Description Electrical polyimide film

 

Ultra thin polyimide film 12.5um 7.5um

Polyimide film is specified for electrical insulation by one relationship above all others: dielectric strength falls as thickness rises. A 25 µm film holds 7.7 kV per 0.025 mm; a 125 µm film, five times thicker, holds only about 2.5 times the voltage. That is why you choose a polyimide film by the breakdown voltage your insulation actually needs - not by picking the thickest film you can afford, and not by accepting "5,000 volts" as a specification from your supplier.

This page gives you the numbers. It covers uncoated polyimide film in the standard thickness band 0.03 – 0.125 mm (25 / 50 / 75 / 125 µm), supplied in roll or slit to width, for Class H motor and transformer insulation, magnet wire, flexible circuits and high-temperature electrical applications.

Thickness: 25 / 50 / 75 / 125 µm standard · 0.015 – 0.25 mm available Width: slit from 8 mm up to 1040 mm Colour: amber / brown, natural Thermal class: H (180 °C) · continuous service −269 °C to +260 °C Forms: roll · slit roll · sheet · die-cut

What This Film Is - and What It Is Not

It is uncoated polyimide film. A cast film of polyimide resin (PMDA–ODA chemistry), amber or brown, supplied without adhesive, without FEP coating and without any backing.

Three products are commonly confused with it - make sure you are specifying the right one:

Product What it is Typical use Where to find it
Uncoated polyimide film (this page) Plain PI film, no coating Slot, interphase and layer insulation; magnet wire wrap; FPC substrate This page
FEP-coated polyimide film (Kapton® FN type) PI film with a heat-sealable fluoropolymer layer on one or both faces Bondable magnet wire insulation and self-adhering wraps - heat seals to itself Ask us separately
Polyimide tape PI film with a silicone or acrylic adhesive Masking during wave soldering and powder coating; high-temperature holding Polyimide film tape

 

Dielectric Strength by Thickness

The core table. Values are for standard polyimide film (DuPont Kapton® HN reference data, AC dielectric strength, 60 Hz).

Thickness Dielectric strength Per mil Breakdown voltage Typical use
25 µm (1 mil) 303 kV/mm 7,700 V/mil ≈ 7.6 kV Thin-wall turn and interturn insulation; where space is critical
50 µm (2 mil) 240 kV/mm 6,100 V/mil ≈ 12.0 kV General slot and layer insulation
75 µm (3 mil) 205 kV/mm 5,200 V/mil ≈ 15.4 kV Higher-voltage slot insulation, transformer interlayer
125 µm (5 mil) 154 kV/mm 3,900 V/mil ≈ 19.3 kV Highest-voltage sections, mec
Amber polyimide PI film for electrical insulation

Thicker film gives you more total withstand voltage but lower dielectric strength per unit thickness. If your constraint is space, thin film is more efficient per millimetre of insulation. If your constraint is mechanical toughness or partial-discharge margin, thick film is the answer. Optimising for the wrong one is a common and expensive specification error.

 

Choosing Film Thickness for Your Working Voltage

The film's breakdown voltage is not your system's rating. Work through it in this order:

Working voltage - the rms voltage the insulation sees in service

Required withstand voltage - apply your safety factor and the insulation-coordination rule you work to (for example IEC 60664-1, or the relevant motor or transformer standard)

Read the required breakdown from the table above and select the thickness that exceeds it

Add margin for temperature, humidity, mechanical stress during winding, and ageing

Test the finished construction - not the bare film

 

High temperature resistant polyimide film 25μm

Worked examples

Working voltage With 3× safety factor Required breakdown Suggested film
1,000 V 3,000 V < 7.6 kV 25 µm - ample margin
3,000 V 9,000 V < 12.0 kV 50 µm
6,000 V 18,000 V < 19.3 kV 125 µm, or reconsider the construction

Other Electrical Properties

Property Typical value Note
Dielectric constant ≈ 3.4 at 1 kHz (range 2.7 – 3.5 by film type and frequency) Stable across frequency and temperature - one reason PI suits high-frequency and high-temperature circuits
Dissipation factor ≈ 0.003 at 60 Hz Low loss
Volume resistivity ≈ 10¹⁷ Ω·cm High insulation resistance, retained at temperature
Surface resistivity ≈ 10¹⁶ Ω -
Dielectric strength at elevated temperature Retained up to the film's thermal limit The defining advantage of polyimide over PET and most other films

 

Slit to Your Required Width

Polyimide film is bought to fit the insulation you are making, so slitting is part of the specification, not an afterthought.

Parameter Range
Minimum slit width 8 mm
Maximum width 1040 mm
Core 3" / 6", paper or plastic
Edge condition Clean, burr-free edge - essential where the film is wrapped under tension
Also available Sheet and die-cut pieces to drawing

Why the minimum width matters: narrow slitting is where most suppliers fail. A film slit to 8 mm has to come off the slitter with a clean edge and consistent tension, or it breaks on the customer's winding machine. Tell us your width and the winding tension and we will confirm what we can hold.

 

Temperature and Insulation Class

Property Value
Thermal class H (180 °C)
Continuous service range −269 °C to +260 °C
Flammability UL 94 VTM-0
Behaviour at temperature

No melting point - the film does not melt and flow; it retains mechanical and dielectric performance across the range

 

 

APPLICATION

 

Polyimide film for foldable OLED display

Class H motor slot insulation

Holds dielectric strength at 180 °C where polyester films cannot

Thickness: 75 – 125 µm

Polyimide film for PCB gold finger masking tape

Interphase and turn-to-turn insulation

Thin enough to fit inside the winding without reducing copper fill

Thickness: 25 – 50 µm

Polyimide film for semiconductor packaging

Dry-type transformer layer insulation

Layer-to-layer dielectric separation at Class H temperature

Thickness: 50 – 125 µm

Polyimide film for flexible heating element

Magnet wire wrap

High dielectric strength in a very thin wall

Thickness: 25 – 50 µm (or FEP-coated for a bonded wall)

Polyimide film for electric vehicle motor insulation

Flexible printed circuits (FPC)

Substrate, coverlay and stiffener at solder temperatures

Thickness: 25 – 50 µm

Polyimide film for aerospace wire insulation

High-temperature cable insulation

Retains insulation resistance at temperature

Thickness: 50 – 125 µm

Polyimide film for transformer voice coil

Voice coil insulation

Withstands coil temperatures in loudspeaker and transducer assemblies

Thickness: 25 – 50 µm

Polyimide film for lithium battery insulation

EV battery and busbar insulation

Dielectric barrier with thermal and mechanical durability

Thickness: 50 – 125 µm

Polyimide film for FPC flexible printed circuit substrate

Die-cut insulation parts

Washers, spacers, shields to drawing

Thickness: Any

How to Specify Your Film

Line Example
Thickness 50 µm or other thickness
Required breakdown voltage ≥ 10 kV, or "for 3 kV working voltage with 3× safety factor"
Slit width 12 mm, ± tolerance
Form Roll / slit roll / sheet / die-cut to drawing
Insulation class Class H (180 °C)
Quantity By weight or by metres, per width

If you would rather not calculate it: send the working voltage, the insulation class and the space available for the insulation, and we will propose a thickness and confirm the slit width.

 

 
Insulation Polyimide Film for Motor

FAQ

What is the dielectric strength of your polyimide film? It depends on thickness, so it must always be quoted with one. Standard values (Kapton® HN reference data): 25 µm ≈ 303 kV/mm (7.6 kV breakdown); 50 µm ≈ 240 kV/mm (12.0 kV); 75 µm ≈ 205 kV/mm (15.4 kV); 125 µm ≈ 154 kV/mm (19.3 kV). Be cautious of any supplier quoting a single voltage figure with no thickness attached.

Why does thicker film have lower dielectric strength? Because dielectric strength is measured per unit thickness. Thicker films contain more volume in which imperfections, voids and partial-discharge sites can exist, so the field they withstand per millimetre is lower - even though the total breakdown voltage is higher.

Which thickness should I use? Start from the working voltage and apply your safety factor, then read the table. As a guide: 25 µm suits thin-wall turn and interturn insulation; 50 µm suits general slot and layer insulation; 75 and 125 µm suit higher-voltage sections and where mechanical toughness matters. Tell us the application and we will confirm.

 

 

Hot Tags: electrical polyimide film, China, suppliers, wholesale, buy, price